Real-time monitoring of Metridia luciferase release from cells upon interaction with model toxic substances by a fully automatic flow setup - A proof of concept

Show simple item record

dc.contributor.author Aguinaga Martínez, Maite V.
dc.contributor.author Jozič, Natali
dc.contributor.author Ducek, Jan
dc.contributor.author Horstkotte, Burkhard
dc.contributor.author Sklenářová, Hana
dc.contributor.author Pávek, Petr
dc.contributor.author Miró, Manuel
dc.date.accessioned 2023-07-07T11:13:38Z
dc.identifier.uri http://hdl.handle.net/11201/161140
dc.description.abstract [eng] This manuscript reports on a fully automatic sequential injection system incorporating a 3D printed module for real-time monitoring of the release of Metridia luciferase from a modified liver epithelial cell line. To this end, a simple and effective approach for the automation of flash-type chemiluminescence assays was developed. The 3D printed module comprised an apical and a basal compartment that enabled monitoring membrane processes on both sides of the cell monolayer aimed at elucidating the direction of luciferase release. A natural release was observed after transfection with the luciferase plasmid by online measurement of the elicited light from the reaction of the synthesized luciferase with the coelenterazine substrate. Model substances for acute toxicity from the group of cholic acids - chenodeoxycholic and deoxycholic acids - were applied at the 1.0 and 0.5 mmol L−1 levels. The tested cholic acids caused changes in cell membrane permeability that was accompanied by an increased luciferase release. The obtained kinetic profiles were evaluated based on the delay between the addition of the toxic substance and the increase of the chemiluminescence signal. All experiments were carried out in a fully automatic system in ca. 5 min per sample in 30 min intervals and no manual interventions were needed for a sampling period of at least 6 h.
dc.format application/pdf
dc.relation.isformatof Versió postprint del document publicat a: https://doi.org/10.1016/j.talanta.2022.123465
dc.relation.ispartof Talanta, 2022, vol. 245, num. 123465, p. 1-7
dc.rights (c) Elsevier B.V., 2022
dc.subject.classification 54 - Química
dc.subject.other 54 - Chemistry. Crystallography. Mineralogy
dc.title Real-time monitoring of Metridia luciferase release from cells upon interaction with model toxic substances by a fully automatic flow setup - A proof of concept
dc.type info:eu-repo/semantics/article
dc.type info:eu-repo/semantics/acceptedVersion
dc.date.updated 2023-07-07T11:13:38Z
dc.date.embargoEndDate info:eu-repo/date/embargoEnd/2024-06-30
dc.embargo 2024-06-30
dc.rights.accessRights info:eu-repo/semantics/embargoedAccess
dc.identifier.doi https://doi.org/10.1016/j.talanta.2022.123465


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Repository


Advanced Search

Browse

My Account

Statistics