Validation of a non-invasive method for the early detection of metabolic syndrome: a diagnostic accuracy test in a working population

Show simple item record

dc.contributor.author Romero-Saldaña, Manuel
dc.contributor.author Tauler, Pedro
dc.contributor.author Vaquero-Abellán, Manuel
dc.contributor.author López-González, Angel-Arturo
dc.contributor.author Fuentes-Jiménez, Francisco-José
dc.contributor.author Aguiló, Antoni
dc.contributor.author Álvarez-Fernández, Carlos
dc.contributor.author Molina-Recio, Guillermo
dc.contributor.author Bennasar-Veny, Miquel
dc.date.accessioned 2023-12-05T08:55:39Z
dc.date.available 2023-12-05T08:55:39Z
dc.identifier.uri http://hdl.handle.net/11201/163000
dc.description.abstract [eng] Objectives A non-invasive method for the early detection of metabolic syndrome (NIM-MetS) using only waist-to-height ratio (WHtR) and blood pressure (BP) has recently been published, with fixed cut-off values for gender and age. The aim of this study was to validate this method in a large sample of Spanish workers. Design A diagnostic test accuracy to assess the validity of the method was performed. Setting Occupational health services. Participants The studies were conducted in 2012-2016 on a sample of 60 799 workers from the Balearic Islands (Spain). Interventions The NCEP-ATP III criteria were used as the gold standard. NIM-MetS has been devised using classification trees (the χ2 automatic interaction detection method). Main outcome measures Anthropometric and biochemical variables to diagnose MetS. Sensitivity, specificity, validity index and Youden Index were determined to analyse the accuracy of the diagnostic test (NIM-MetS). Results With regard to the validation of the method, sensitivity was 54.7%, specificity 94.9% and the Validity Index 91.2%. The cut-off value for WHtR was 0.54, ranging from 0.51 (lower age group) to 0.56 (higher age group). Variables more closely associated with MetS were WHtR (area under the curve (AUC)=0.85; 95% CI 0.84 to 0.86) and systolic BP (AUC=0.79; 95% CI 0.78 to 0.80)). The final cut-off values for the non-invasive method were WHtR ≥0.56 and BP ≥128/80 mm Hg, which includes four levels of MetS risk (very low, low, moderate and high). Conclusions The analysed method has shown a high validity index (higher than 91%) for the early detection of MetS. It is a non-invasive method that is easy to apply and interpret in any healthcare setting. This method provides a scale of MetS risk which allows more accurate detection and more effective intervention.
dc.format application/pdf
dc.relation.isformatof Reproducció del document publicat a: https://doi.org/10.1136/bmjopen-2017-020476
dc.relation.ispartof Bmj Open, 2018, vol. 8, num. 10, p. e020476-1-e020476-11
dc.rights cc-by (c) Romero-Saldaña, Manuel et al., 2018
dc.rights.uri https://creativecommons.org/licenses/by/4.0/
dc.subject.classification 57 - Biologia
dc.subject.classification 614 - Higiene i salut pública. Contaminació. Prevenció d'accidents. Infermeria
dc.subject.classification Ciències de la salut
dc.subject.other 57 - Biological sciences in general
dc.subject.other 614 - Public health and hygiene. Accident prevention
dc.subject.other Medical sciences
dc.title Validation of a non-invasive method for the early detection of metabolic syndrome: a diagnostic accuracy test in a working population
dc.type info:eu-repo/semantics/article
dc.type info:eu-repo/semantics/publishedVersion
dc.date.updated 2023-12-05T08:55:39Z
dc.rights.accessRights info:eu-repo/semantics/openAccess
dc.identifier.doi https://doi.org/10.1136/bmjopen-2017-020476


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

cc-by (c) Romero-Saldaña, Manuel et al., 2018 Except where otherwise noted, this item's license is described as cc-by (c) Romero-Saldaña, Manuel et al., 2018

Search Repository


Advanced Search

Browse

My Account

Statistics