On-site extraction using a 3D printed device coated with Zn/Co-ZIF-derived carbon followed by an on-line SIA-HPLC-FL system for fluoroquinolones determination in wastewater

Show simple item record

dc.contributor.author Barzallo, D.
dc.contributor.author Están, A.
dc.contributor.author Crespí, N.
dc.contributor.author Palomino, C.
dc.contributor.author Turnes, G.
dc.contributor.author Palacio, E.
dc.contributor.author Ferrer, L.
dc.date.accessioned 2024-07-25T08:32:00Z
dc.date.available 2024-07-25T08:32:00Z
dc.identifier.uri http://hdl.handle.net/11201/165880
dc.description.abstract [eng] A 3D printed device covered with Zn/Co-ZIF-derived carbon allows the on-site extraction of fluoroquinolones (FQs) from wastewater, avoiding the sample transportation to the laboratory, and the subsequent elution, separation and determination using an on-line flow system based on sequential injection analysis (SIA) coupled to HPLC-FL. Several parameters that affect the extraction efficiency and desorption were optimized including the sorption phase immobilization technique on the 3D device, extraction time, pH effect, sample volume as well as the type of eluent, eluent volume, and flow rate. Under optimum conditions, detection limits of 3–9 ng L−1 were achieved for norfloxacin, ciprofloxacin, danofloxacin, enrofloxacin and difloxacin. The precision expressed as relative standard deviation (%RSD, n = 3), showed intraday and interday ranges of 1.5–5.3% and 2.8–5.7%, respectively, demonstrating a good precision of the proposed methodology. To assess matrix effects and accuracy of the proposed method in real samples, recovery studies were performed without and with FQs spiked at different concentrations (0.5–10 μg L−1) to wastewater samples, showing good recoveries in the range of 91–104%. The results allow to confirm the applicability of MOF-derived carbons as adsorbents for on-site extraction, and the satisfactory separation and quantification of FQs by a SIA-HPLC-FL on-line system after their desorption with small eluent volumes.
dc.format application/pdf
dc.relation.isformatof Versió postprint del document publicat a: https://doi.org/10.1016/j.talanta.2024.125897
dc.relation.ispartof Talanta, 2024, vol. 273
dc.rights (c) Elsevier B.V., 2024
dc.subject.classification 5 - Ciències pures i naturals
dc.subject.other 5 - Mathematical and Natural Sciences
dc.title On-site extraction using a 3D printed device coated with Zn/Co-ZIF-derived carbon followed by an on-line SIA-HPLC-FL system for fluoroquinolones determination in wastewater
dc.type info:eu-repo/semantics/article
dc.type info:eu-repo/semantics/acceptedVersion
dc.date.updated 2024-07-25T08:32:01Z
dc.rights.accessRights info:eu-repo/semantics/openAccess
dc.identifier.doi https://doi.org/10.1016/j.talanta.2024.125897


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Repository


Advanced Search

Browse

My Account

Statistics