Validation of a Clinical Scale for Early Detection of Infections at the Exit Site of Central Venous Catheters for Hemodialysis

Show simple item record

dc.contributor.author Cobo-Sánchez, J.L.
dc.contributor.author Blanco-Mavillard, I.
dc.contributor.author Pelayo-Alonso, R.
dc.contributor.author Mancebo-Salas, N.
dc.contributor.author Fernández-Fernández, I.
dc.contributor.author Larrañeta-Inda, I.
dc.contributor.author Ulzurrun-García, A.
dc.contributor.author González-García, F.
dc.contributor.author Hernando-García, J.
dc.contributor.author Rollán-de la Sota, M.J.
dc.contributor.author Vieira-Barbosa Lopes, L.M.
dc.contributor.author Prieto-Rebollo, M.D.R.
dc.contributor.author Sesmero-Ramos, C.
dc.contributor.author Casas-Cuesta, R.
dc.contributor.author Alcántara-Crespo, M.
dc.contributor.author De Pedro-Gómez, J.E.
dc.contributor.author Sánchez-Villar I.
dc.contributor.author Jaume-Riutort, C.
dc.date.accessioned 2025-06-25T07:05:33Z
dc.date.available 2025-06-25T07:05:33Z
dc.identifier.citation Cobo-Sánchez, J.L., Blanco-Mavillard, I., Pelayo-Alonso, R., Mancebo-Salas, N., Fernández-Fernández, I., Larrañeta-Inda, I., Ulzurrun-García, A, Sánchez-Villar, I., González-García, F., Hernando-García J., Rollán-de la Sota, M.J., Vieira-Barbosa Lopes, L.M., Prieto-Rebollo, M.D.R., Sesmero-Ramos, C., Jaume-Riutort, C., Casas-Cuesta, R., Alcántara-Crespo, M., i De Pedro-Gómez, J.E. (2024). Validation of a Clinical Scale for Early Detection of Infections at the Exit Site of Central Venous Catheters for Hemodialysis. Kidney International Reports, 9, 2739-2749. https://doi.org/10.1016/j.ekir.2024.06.034 ca
dc.identifier.uri http://hdl.handle.net/11201/170509
dc.description.abstract [eng] Introduction: Exit-site infections (ESI) of central venous catheters for hemodialysis (CVC-HD) has been associated with early catheter removal and an increased risk of CVC-HD related bacteremia. No specific clinical scales to predict ESI have previously been validated. Methods: A multicenter prospective cohort study was performed to validate the proposed scale, which is based on the following 5 signs and symptoms: (i) pain at exit site during interdialytic period; (ii) hyperemia or erythema ≥2 cm from exit site; (iii) inflammation, induration, or swelling at exit site; (iv) fever ≥38 °C not attributable to other causes, and (v) obvious abscess or purulent exudate at the exit site. Adult patients with a tunneled CVC-HD for at least 1 month after insertion has been included. During each hemodialysis session, the exit site was assessed with the proposed scale by nurses. If any item was present, a pericatheter skin swab culture was collected: positive results were gold standard. The scale was validated using receiver operating characteristic (ROC) curves and logistic regression analysis. For this purpose, the logit function was applied, and the ESI probability calculated, as elogit ESI/1 + elogit ESI. Results: Three hundred thirty-seven CVC-HDs from 310 patients were analyzed, producing 515 cultures (117 infected and 398 healthy). The final version of the scale includes the following 3 signs and symptoms, which present the greatest predictive capacity: (i) pain at exit site during interdialytic period, (ii) hyperemia or erythema ≥2 cm from exit site, and (iii) abscess or purulent exudate at the exit site. The final version generated an area under the ROC curve (AUC) of 88.3% (95% confidence interval [CI]: 85.2%–91%; <em>P</em> < 0.001), Youden index 0.7557 ≈ 1, sensitivity 80.34% (95% CI: 71.36%–87.71%) and specificity 95.23% (95% CI: 92.73%–97%). Conclusions: The validation shows that the scale has good predictive properties, detecting approximately 90% of ESI with very acceptable validity parameters. en
dc.format application/pdf en
dc.format.extent 2739-2749
dc.publisher Elsevier
dc.relation.ispartof Kidney International Reports, 2024, vol. 9, p. 2739-2749
dc.rights Attribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.classification 614 - Higiene i salut pública. Contaminació. Prevenció d'accidents. Infermeria ca
dc.subject.other 614 - Public health and hygiene. Accident prevention en
dc.title Validation of a Clinical Scale for Early Detection of Infections at the Exit Site of Central Venous Catheters for Hemodialysis en
dc.type info:eu-repo/semantics/article
dc.type info:eu-repo/semantics/publishedVersion
dc.type Article
dc.date.updated 2025-06-25T07:05:33Z
dc.subject.keywords reproducibility of results en
dc.subject.keywords Early diagnoses en
dc.subject.keywords Central venous catheter en
dc.rights.accessRights info:eu-repo/semantics/openAccess
dc.identifier.doi https://doi.org/10.1016/j.ekir.2024.06.034


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 International Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 International

Search Repository


Advanced Search

Browse

My Account

Statistics